• High Power 128 Ports Optical Amplifier
  • High Power 128 Ports Optical Amplifier
  • High Power 128 Ports Optical Amplifier
  • High Power 128 Ports Optical Amplifier
  • High Power 128 Ports Optical Amplifier
  • High Power 128 Ports Optical Amplifier

High Power 128 Ports Optical Amplifier

Type: Fiber Transceiver
Wiring Devices: ODF
Certification: CE, ISO, RoHS
Condition: New
Operating Wavelength (Nm): 1540~1565
Input Optical Power(dBm): -10~+10
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Installation Instructions
  • Product Parameters
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
FWA-1550H-128
Nominal Input Optical Power (dBm)
3
Optical Connector(in/out)
Sc/APC LC/APC
Pump Work Quantity (N)
3
Saturated Output Power (dBm)
20
Power Supplies (VAC)
115~265(Draw-out Plug)
Power Supplies (VDC)
48(Draw-out Plug)-Optional
Operating Temperature
0~50
Size (mm)
2u Rack
Transport Package
Case Packing
Specification
CE, ISO, RoHs
Trademark
FULLWELL (OEM, ODM available)
Origin
Zhejiang, China
Production Capacity
8000PCS/Month

Product Description

High Power 128 Ports Optical Amplifier
High Power 128 Ports Optical Amplifier
High Power 128 Ports Optical Amplifier
High Power 128 Ports Optical Amplifier
High Power 128 Ports Optical Amplifier

 
Product Description

FWA-1550H series EYDFA optical amplifier is the latest equipment of optical transmitting system for CATV FTTH/FTTP. In detail, there is one way CATV inputoutput 1550nm with 30 to 40dBm total power.
Ordinary erbium-doped fiber amplifier (EDFA) has the advantages of low noise, high gain, wider bandwidth, highly efficient pumping, and stable operating, which is widely used in CATV systems. However, along with the implementation of fiber to the house (FTTH), system C/N will be worse significantly when EDFA uses as cascade amplification. Therefore, EDFA is required to produce high saturation output power and low distortion as shown as 13dBm to 23dBm (approximate. 27dBm limited) for EDFA saturated output power. Moreover, the gain fiber of EDFA is single-mode and single-packed fiber. The optic of the pump is directly coupled to the fiber but the diameter of the fiber is very small therefore it requires a single mode of pump optic. The semiconductor of single mode only supports hundreds of milliwatts of output power and it is limited by the area of the pump which makes high-power pump optic cannot coupling. It consequently causes serious output power of the optical laser. In case, it develops double-cladding fiber internationally and solves the problem of the listed weakness of single-packed fiber which improves 1 to 2 levels for output power. It then drives the development of high-power optical amplifiers. After three years of research, high-power ytterbium-erbium co-doped double-cladding fiber amplifier was developed to fit the requirement of FTTH and FTTB after conquering many technical difficulties.
This series product adopts LUMENTUM, IPG, etc multimode high power pump laser as the pump source, and American OFS closed beam splitter as the double-cladding synthesizer. Built-in stable optical power circuit and laser thermoelectricity freezer guarantee the best performance and long life cycle operating. Microprocessor software monitors the operating status of the laser which shows on the LCD. Once the operating parameter of the laser deviates from the range of the set value, the microprocessor will cut the power supply of the laser automatically and the red light turn will turn on with an alarm (prompting a fault caused on LCD).

1.2 Features
1.2.1 High Quality: Adoption of multimode high power pump laser and power is optimized by software which maximizes lower NF of EDFA rival to normal EDFA. It makes the system get superior CNR through power optimize balancing technique.
1.2.2 Reliability: adoption of 19″2U standard case, built-in high-performance external modular switching power supply, operating under AC90 to 265V, optional DC48V power supply (pre-order) hot-plugging supported, automatic temperature control case heat dissipation with dual power cold&hot backup.
1.2.3 Intuitive: The microprocessor monitors the operating status of the pump laser which is the most valuable part of the equipment, operating parameters show on the LCD display.
1.2.4 Network Management: Optional type status monitoring transponder certainly satisfy national, SCTE, HMS, and WEB standard, it realizes network management monitoring function.
1.2.5 Adjustable Output Power: The equipment is advanced designed which satisfies a bigger range of adjustment from lower to -2dBm (special offer).
1.2.6 High Power Output: Combined output power has a maximum of 30~45dBm and multiple output configuration is available for users' requirement.
1.2.7 WDM Insertion: It is available to integrate the FWDM module if the user needs which is convenient when combining GPON, and EPON.
1.2.8 Connecting Safety Mode: To prevent the optical patch cord end face from being burnt when the optical output is connected, enable this mode to reduce the output power direct to 19dBm during connection. Once turn off this mode, it returns to the original set power.
 

Installation Instructions

 

High Power 128 Ports Optical Amplifier
The machine's microprocessor software owns the laser working condition monitoring, digital panel displays, fault alarm, network management, and other functions. For inquiries, press the MENU button panel, and then press ENTER to confirm, press UP or DOWN to search or set different parameters and setting items.

1. After power-on upside display:"CATV EDFA",downside display:"LASER POWER OFF"(see 4-1-1)," CATV EDFA"means name of equipment,"LASER POWER OFF"means pump is powered off;Switch on laser lock and shows " CATV EDFA""FWA-1550H-32×XX" normally(see 4-1-2),"FWA-1550H-32×XX" means models,32 means 32 ways output,XX means output power in unit of dBm.

 
 
2. Inquiry FunctionPress the Menu button entry inquiry parameter inquiry(4-2-1)then press ENTER confirmed power supply module ±5V voltage 1 inquiry (4-2-2), press DOWN inquires 2 power module ±5V (4-2-3); press UP again entry inquiry of prepositional amplifier laser current and temperature(4-2-4), inquiry of cooling or hitting current and power of preposition amplifier(4-2-5), inquiry of pump 1 current and pump 2 current(4-2-6)inquiry of pump 1 temperature and pump 2 temperature(4-2-7), inquiry of case temperature and input power(4-2-8), inquiry of output power 1 and 2(4-2-9)inquiry of software edition and data(4-2-10)inquiry of equipment serial number(4-2-11).
3. Setting Function: press the MENU twice, get into parameter setting interface(4-3-1), press ENTER to confirm to get into setting, first item: "safety mode OFF"(4-3-2)/ON(4-3-3), press ENTER to confirm to"OFF", press DOWN to choose to"ON", press again ENTER to confirm, which means the end of this setting; press DOWN to set next item: IP address(4-3-4), subnet mask(4-3-5), admin gateway(4-3-6), server 1 address(4-3-7), server 2 address(4-3-8), fan switch and power module operation status(4-3-9), output power 1 and 2(4-3-10)setting, press ENTER to confirm setting item, press UP or DOWN button to choose setting content, press again ENTER to confirm this item, then press UP or DOWN to adjust each parameter, final press ENTER to confirm the end of the setting.

 
High Power 128 Ports Optical Amplifier


 
Product Parameters
ITEMS UNIT INDICATORS
Optical Operating Wavelength nm 1535~1565
Input Optical Power Range dBm -10~+10
Nominal Input Optical Power dBm +3
Maximum Alarm Value dBm >+10 front panel display alarm
Minimum Alarm Value dBm ≤-10 front panel display and power off
Noise Ratio dB 5.0 (0 dBm,@1550nM)
Gain Flatness dB <±0.3
Optical Power Output Stability dB <±0.5
Polarization Sensitivity dB <0.2
Polarization Mode Dispersion Ps <0.5
Input End Pump Leakage Power  dB ≤-30
Output End Pump Leakage Power  dB ≤-30
Optical Input, Output Return Loss  dB >45 (APC Stepped Face)
Pump Operating Number No. 2~4
Rated Output Power dBm 27~40
Linker(IN) - SC/APC
Linker(OUT) - SC/APC
C/N dB 48(comment 1)
C/CTB  dB ≥63(comment 1)
C/CSO  dB ≥63(comment 1)
Power Supply/Consumption V/W AC90~250/<45(hot-plugging single power)
Operating/Storage Temperature ºC -20~50/-30~70
Operating/Storage Humidity % 5~90
Case Size mm 446×384×86
Network Management Connector / RJ45(following national network management standard, supports WEB)
Comment:
1, Optical Link Test provides link index by measuring optical transmitter FWT-1550DT-2X7 and receiver FWR-8610.
2, The main performance index above accords with GY/T 184-2002 CATV analog optical amplifier technical requirement and measuring method.
Certifications

High Power 128 Ports Optical Amplifier

FAQ

 

1. What are your terms of payment? 
Usually, we can accept T/T, PayPal, and Western Union. You can select the terms of payment which is more convenient for you. 

2. What about the lead time? 
Usually, if there is a stock of goods, we will deliver the goods within 3~5 workdays after we receive the payment. 

3. How about the shipping? 
Usually, we will deliver the goods via International Express like FedEx, DHL, TNT, UPS, and so on. The door-to-door delivery service will be provided. 

4. How can I place an order? 
(1) An agreement is achieved on the product price and product specifications. 
(2) We make a proforma invoice for your confirmation. 
(3) When you agree on the proforma invoice, you make the payment. 
(4) We deliver the goods after we receive your payment. 

5. Can you do OEM for us? 
Yes. If there is a certain order quantity, we can do OEM including printing, logo, and customized model for you. 

6. What are the advantages of your products? 
  1. Good quality and competitive prices. 
  2. Strict quality control during the production process.
  3. Professional operations in processes of production, sales, assembling, packaging, and shipping.
  4. Good after-sale service. Professional online technical support can be provided. Moreover, if there is any problem with the goods, we will help to solve the problem or provide replacement of the goods. 

Send your message to this supplier

*From:
*To:
avatar Miss Helen Ye
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001
Export Year
2005-06-10